Skip to content Skip to footer

Automatic Linear Vial Washing Machine Model 120

Basic Machine – Standard Supply

  • GMP Model machine construction.

  • One set of change parts suitable for 5 ml to 30 ml vials with 20 mm neck diameter.

  • 3 Nos. SS-316 tanks, capacity 50 litres each.

  • 3 Nos. SS-316 centrifugal pumps – one each for re-circulation water, DM water, and WFI water.

  • 4 Nos. SS-316 filter housings with cartridges:

    • 1 No. for re-circulation water: 10” size, 10 micron

    • 1 No. for fresh DM water: 10” size, 5 micron

    • 1 No. for fresh WFI water: 10” size, 5 micron

    • 1 No. for compressed air: 5” size, 0.2 micron

  • 4 Nos. glycerin-filled pressure gauges.

  • Inbuilt SS-304 wire mesh infeed conveyor.

  • A.C. frequency drive for speed control.

  • Individual solenoid valves for wash media operation.

  • All water contact pipe fittings manufactured from SS-316 material.

  • Gear box and motor for main machine and infeed conveyor.

  • Emergency stop switches provided on control panel and outfeed side.

  • Outfeed can be directly connected to sterilizing tunnel or used for tray collection.

  • Output: Up to 120 VPM (depending upon vial size).

  • Push-button based operating controls.

SKU: 14608ecbd7c6 Category: Product ID: 8167

Description

Safety & Interlocks

  • Main motor overload – machine stop

  • Infeed lifter jam – machine stop

  • Emergency stop (both ends) – machine stop

  • Outfeed lifter jam – machine stop

  • Outfeed pusher jam – machine stop

  • Outfeed prism jam – machine stop

  • Re-circulation water level low – light indication / machine stop

  • DM water level low – light indication / machine stop

  • WFI water level low – light indication / machine stop


Change Parts & Size Capability

  • Machine capable to run up to maximum 30 ml vial.

  • Changeover for 2 ml vials with 13 mm neck diameter.

  • Complete channel set (40 Nos.) with 400 vial holder cups supplied.


Washing Process Details

Internal Washing Sequence

  1. Compressed air

  2. Re-circulated water – drain

  3. Re-circulated water – drain

  4. Compressed air

  5. Fresh DM water – collected in re-circulation tank

  6. Compressed air

  7. Fresh DM water – collected in re-circulation tank

  8. Compressed air

  9. Fresh WFI water – collected in re-circulation tank

  10. Compressed air

External Washing

  • 2nd wash: Re-circulated water

  • 7th wash: Fresh DM water

  • Washing sequence offers operational flexibility.

  • Each wash media passes through individual and separate spray pipes and nozzles.


Machine Configuration

  • Number of cups per row: 10 Nos.

  • Number of channels: 40 Nos.

  • Total number of cups: 400 cups per machine

  • 10 inner washing spray pipes and 2 outer washing spray pipes

  • 100 inner washing nozzles and 20 outer washing nozzles


Optional Accessories – PLC Based System

  • PLC with HMI touch screen (Delta make)

  • Three-level access: Operator / Supervisor / Maintenance

  • All interlocks displayed on HMI with buzzer indication

  • Jog / inching operation through HMI

  • Pressure transmitters for all wash media:

    • Re-circulation water pressure low – machine stop

    • DM water pressure low – machine stop

    • WFI water pressure low – machine stop

    • Compressed air pressure low – machine stop


Material of Construction

  • Machine frame: SS-304

  • Door set: SS-304

  • Control panel: SS-304

  • All water contact parts: SS-316 / HDPE (food grade)

  • Infeed conveyor: SS-304 wire mesh

  • Pocket drive chain: SS-304

  • Vial holder cups: HDPE – food grade

  • Flexible pipes: Silicone – food grade

  • Pressure gauges: SS, glycerin filled

  • All shafts: SS-304

  • Pump contact parts: SS-316

  • Filter housing: SS-316

  • Tanks: 3 Nos. SS-316 – 50 litres each

  • All pipe fittings: SS sanitary type


Make of Bought-Out Items

  • Contactors & relays: Telemechanic / Schneider

  • Limit switches: Teknic / BCH / Schneider

  • Pumps: CNP

  • Pressure gauges: Shreeji

  • Main gearbox & motor: Bonvario

  • Conveyor gearbox & motor: Bonvario

  • Solenoid valves: Rotex

  • A.C. drive: Delta

  • PLC & HMI: Delta (optional)


Utilities Required at Site

  1. Power: Total 5 HP, 3-phase, 50 Hz

    • 1 HP for each pump

    • 1 HP for machine

    • 0.25 HP for conveyor

  2. Compressed Air: 35–45 CFM at 4 kg/cm², to be provided from site utility